Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Soc Mass Spectrom ; 33(9): 1659-1677, 2022 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-36018776

RESUMO

The multi-attribute method (MAM) was conceived as a single assay to potentially replace multiple single-attribute assays that have long been used in process development and quality control (QC) for protein therapeutics. MAM is rooted in traditional peptide mapping methods; it leverages mass spectrometry (MS) detection for confident identification and quantitation of many types of protein attributes that may be targeted for monitoring. While MAM has been widely explored across the industry, it has yet to gain a strong foothold within QC laboratories as a replacement method for established orthogonal platforms. Members of the MAM consortium recently undertook an interlaboratory study to evaluate the industry-wide status of MAM. Here we present the results of this study as they pertain to the targeted attribute analytics component of MAM, including investigation into the sources of variability between laboratories and comparison of MAM data to orthogonal methods. These results are made available with an eye toward aiding the community in further optimizing the method to enable its more frequent use in the QC environment.


Assuntos
Benchmarking , Proteínas , Espectrometria de Massas/métodos , Mapeamento de Peptídeos/métodos , Controle de Qualidade
2.
J Am Soc Mass Spectrom ; 32(4): 913-928, 2021 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-33710905

RESUMO

The Multi-Attribute Method (MAM) Consortium was initially formed as a venue to harmonize best practices, share experiences, and generate innovative methodologies to facilitate widespread integration of the MAM platform, which is an emerging ultra-high-performance liquid chromatography-mass spectrometry application. Successful implementation of MAM as a purity-indicating assay requires new peak detection (NPD) of potential process- and/or product-related impurities. The NPD interlaboratory study described herein was carried out by the MAM Consortium to report on the industry-wide performance of NPD using predigested samples of the NISTmAb Reference Material 8671. Results from 28 participating laboratories show that the NPD parameters being utilized across the industry are representative of high-resolution MS performance capabilities. Certain elements of NPD, including common sources of variability in the number of new peaks detected, that are critical to the performance of the purity function of MAM were identified in this study and are reported here as a means to further refine the methodology and accelerate adoption into manufacturer-specific protein therapeutic product life cycles.

3.
MAbs ; 3(4): 387-95, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21654206

RESUMO

Comparability studies lie at the heart of assessments that evaluate differences amongst manufacturing processes and stability studies of protein therapeutics. Low resolution chromatographic and electrophoretic methods facilitate quantitation, but do not always yield detailed insight into the effect of the manufacturing change or environmental stress. Conversely, mass spectrometry (MS) can provide high resolution information on the molecule, but conventional methods are not very quantitative. This gap can be reconciled by use of a stable isotope-tagged reference standard (SITRS), a version of the analyte protein that is uniformly labeled (13)C6-arginine and (13)C6-lysine. The SITRS serves as an internal control that is trypsin-digested and analyzed by liquid chromatography (LC)-MS with the analyte sample. The ratio of the ion intensities of each unlabeled and labeled peptide pair is then compared to that of other sample(s). A comparison of these ratios provides a readily accessible way to spot even minute differences among samples. In a study of a monoclonal antibody (mAb) spiked with varying amounts of the same antibody bearing point mutations, peptides containing the mutations were readily identified and quantified at concentrations as low as 2% relative to unmodified peptides. The method is robust, reproducible and produced a linear response for every peptide that was monitored. The method was also successfully used to distinguish between two batches of a mAb that were produced in two different cell lines while two batches produced from the same cell line were found to be highly comparable. Finally, the use of the SITRS method in the comparison of two stressed mAb samples enabled the identification of sites susceptible to deamidation and oxidation, as well as their quantitation. The experimental results indicate that use of a SITRS in a peptide mapping experiment with MS detection enables sensitive and quantitative comparability studies of proteins at high resolution.


Assuntos
Anticorpos Monoclonais/química , Isótopos de Carbono/química , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Proteínas/normas , Animais , Anticorpos Monoclonais/biossíntese , Anticorpos Monoclonais/uso terapêutico , Produtos Biológicos , Células CHO , Cricetinae , Células HEK293 , Humanos , Marcação por Isótopo/métodos , Mapeamento de Peptídeos , Proteínas/metabolismo , Proteínas/uso terapêutico , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Anal Biochem ; 414(1): 147-53, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21396346

RESUMO

A method including protein A purification, limited Lys-C digestion, and mass spectrometry analysis was used in the study to quantify a recombinant monoclonal antibody in cynomolgus monkey serum. The same antibody that was isotopically labeled was used as an internal standard. Interferences from serum proteins were first significantly reduced by protein A purification and then by limited Lys-C digestion of protein A bound IgG, including both monkey and the recombinant IgG. Fab fragment of the recombinant human IgG was analyzed directly by LC-MS, while monkey IgG and the Fc fragment of the recombinant human IgG remained bound to protein A resin. Quantitation was achieved by measuring the peak intensity of the Fab from the recombinant human IgG and comparing it to that of the Fab from the stable isotope-labeled internal standard. The results were in good agreement with the values from ELISA. LC-MS can therefore be used as a complementary approach to ELISA to quantify recombinant monoclonal antibodies in serum for pharmacokinetics studies and it can also be used where specific reagents such as antigens are not readily available for ELISA.


Assuntos
Anticorpos Monoclonais/sangue , Espectrometria de Massas/métodos , Animais , Células CHO , Cromatografia Líquida/métodos , Cricetinae , Cricetulus , Haplorrinos/sangue , Proteínas Recombinantes/sangue
5.
RNA ; 13(5): 793-800, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17379815

RESUMO

Three new photoreactive tRNA derivatives have been synthesized for use as probes of the peptidyl transferase center of the ribosome. In two of these derivatives, the 3' adenosine of yeast tRNA(Phe) has been replaced by either 2-azidodeoxyadenosine or 2-azido-2'-O-methyl adenosine, while in a third the 3'-terminal 2-azidodeoxyadenosine of the tRNA is joined to puromycin via a phosphoramidate linkage to generate a photoreactive transition-state analog. All three derivatives bind to the P site of 70S ribosomes with affinities similar to that of unmodified tRNA(Phe) and can be cross-linked to components of the 50S ribosomal subunit by irradiation with near-UV light. Characteristic differences in the cross-linking patterns suggest that these tRNA derivatives can be used to follow subtle changes in the position of the tRNA relative to the components of the peptidyl transferase center.


Assuntos
Peptidil Transferases/metabolismo , Fotoquímica/métodos , RNA de Transferência/química , RNA de Transferência/metabolismo , Ribossomos/metabolismo , Reagentes de Ligações Cruzadas/química , Desoxiadenosinas/química , Escherichia coli/genética , Escherichia coli/metabolismo , Peptidil Transferases/química , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...